Centrifuge Card Plazma Gel 12/24 Гурӯҳбандии хун чопкунии Id Serological

Барномаҳо: ●ABO blood type test test
●Rh blood group antigen test
●Irregular antibody screening
●Cross match
●HDN detection
●Platelet antibody screening
●Platelet crossmatch
Макс Суръат 3500rpm
Max.RCF 1554 хг
Иқтидори максималӣ Кортҳои 24
Роторҳои мувофиқ Disk card rotors
намоиш LCD
Number модел: XK-12B
сертификатсия: CE, ISO13485, ISO9001: 2015
кафолат Кафолати 1 сол барои тамоми мошин, 3 сол кафолат барои компрессор ва 5 сол кафолат барои мотор. Қисмҳои ройгони иваз ва интиқол дар доираи кафолат.
  • Тавсифи
  • Видео
  • Тафсилот техникӣ
  • Роторҳо ва лавозимот
  • Афзалияти рақобат

Micro column gel technology is extensively employed in blood serology, routine serum detection, red blood cell washing, microcolumn gel immunoassay experiments, and other applications due to its standardized operation and sensitive testing capabilities. The XK-12B blood gel card desktop low-speed centrifuge with a 12/24 card rotor meets the standard operation requirements for batch processing. The system features microcomputer control and automatic imbalance detection technology, ensuring easy operation and precise detection results. This instrument is essential for experimental hematology in hospitals and blood banks.

Principle for Blood Gel Card(ID-Card) Centrifuge

The principle behind the Blood Gel Card Centrifuge is based on the microcolumn gel immunoreaction, specifically the red blood cell agglutination test, also known as microcolumn gel hemagglutination assay (MGHA). Within the microcolumn gel tube, the red blood cells and their corresponding antibodies combine to form a clump of red blood cells. Through low-speed centrifugation, the clot is positioned either on the surface or within the gel, while the red blood cells that are not bound to the antibody settle at the bottom of the tube (the tip of the tube bottom).

афзалиятҳо

The advantages of Micro Column Gel Technology include its simplicity of operation, lack of washing and confirmation tests for negative results, which solves the problem of the Coombs test being difficult to routinely apply in clinical practice due to its complexity and time-consuming nature. It also promotes the incomplete antibody detection theory to become the clinical "gold standard". The system can process multiple specimens at once (12/24 cards), enabling the detection of a large number of clinical specimens. Additionally, it offers advantages such as accuracy, sensitivity, minimal specimen consumption, long-term storage of results, easy standardization, and safer operation.

Paternity Testing Method

The Paternity Testing Method involves the use of ABO blood type positive and negative type and RhD blood type test cards to detect human ABO and RhD antigens. The column agglutination method (microcolumn gel method) is a commonly used immunological method for blood group identification, in which red blood cell antigens and corresponding antibodies agglutinate in a microcolumn gel medium. This method is standardized and quantified, ensuring the accuracy of the results.

The following steps are involved in the process:

1.Blood sample collection (note: samples containing abnormally increased serum protein should be washed sufficiently before use).

2. Blood sample processing:

(i) Centrifuge the anticoagulated whole blood sample at 900~1000g centrifugal force for 5 minutes, the lower layer is the concentrated packed red blood cells with a concentration of about 80%. Carefully absorb the upper plasma in another test tube, which can be used directly in the experiment.

(ii) Dilute the packed red blood cells to be tested: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots. (iii) Dilute the red blood cells: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots.

3. Blood type card operation:

1) Mark the prepared micro-living gel reagent card.

2) Add the prepared red blood cell suspension to the first to fourth tubes respectively, and add the diluted inverted red blood cells to the fifth to sixth tubes.

3) Immediately centrifuge for 5 minutes (900rpm for 2 minutes, 1500rpm for 3 minutes) in a blood type card centrifuge, and take out the result of the naked eye judgment.

лоиҳа

● Microprocessor control with Brushless Motor. Accurate speed control.

● Easy operation. Colorful digital screen indicates all running parameters. Automatic lid -open alarm when the instrument is off.

● Professional programming design. No need for manual setting. Just run it.

TBTC12 Centrifuge

Корбарписанд

● Қулфи худкори сарпӯш ва нигоҳдорӣ дар ҷараёни ротор.

● Системаи худшиносӣ бо пӯшиши камеравии мустаҳкам ва муҳофизатӣ.

● Технологияи патентии "Хомуш", суръати баландтарини амалиёт камтар аз 50 децибел аст.

● Табдили автоматии чархзанӣ/rcf.

TBTC12 Centrifuge

бехатарӣ

● Мувофиқи қоидаҳои байналмилалии бехатарӣ истеҳсол карда шудааст (масалан, IEC 61010).

● Бехатарӣ Қулфи сарпӯши барқӣ, ҳангоми кор кардани ротор дар кушода намешавад ва ҳангоми кушодани сар ва пайдо шудани рамзи хато мошин кор намекунад.

● Ба ҳолати фавқулодда раҳо кардани қулфи сарпӯш ҳангоми қатъи барқ ​​(ҳангоми қатъи ғайричашмдошти барқ ​​хеле муфид аст).

● Муҳофизати бехатарӣ барои суръати аз ҳад зиёд барои таъмини бехатарии мошини одам сохта шудааст.

TBTC12 Centrifuge

Диапазони суръат (rpm) 0-3500rpm танзимшаванда Садо (dBA) ≦50 dB(A)
Иқтидори максималӣ (мл) 24 cards Андозаи (мм) 430*320*250mm(12 cards)
440*400*230mm(24 cards)
Диапазони RCF (xg) 0-1554xg танзимшаванда Вазни холис 13 KG (with 12 cards)
22KG (with 24 cards)
таъмини барқ AC220V, 50HZ, 5A, 60W
, № Банди имконият Суръати гардиш Max.RCF Time Шарҳ

NO.1

Номаълум-3

Pre-centrifuge program group Кортҳои 12 3500r / min 1232хг 1 дақиқа Program group can be set for different blood type cards.

NO.2

Номаълум-3

Test program group Кортҳои 12 900r / min 81хг Дақиқаи 2
1500r / min 226хг Дақиқаи 3

NO.1

4

Pre-centrifuge program group Кортҳои 24 3500r / min 1554хг 1 дақиқа

NO.2

4

Test program group Кортҳои 24 800r / min 81хг Дақиқаи 2
1335r / min 226хг Дақиқаи 3
Номаълум-3

1.Истеҳсолкунандаи центрифугаи касбӣ, нархи рақобатпазир.

2.ISO9001, ISO13485, CE, SFDA Сертификатсия, ҳама мошинҳо пеш аз интиқол аз санҷиши сифат ва бастабандии хуб мегузаранд.

3.Дастгирии техникии дарозмуддат ва хидматрасонии касбии мизоҷон дар ҳар марҳилаи фурӯш, таҳвил ва амалиёт. Дастаи хидматрасонии баландихтисос ва ботаҷрибаи мо ба шумо сатҳи беназири дастгирӣ барои хариди шумо барои тамоми умри он.

4.Мо инчунин метавонем ҳалли фармоиширо барои талаботи махсуси мизоҷон пешниҳод кунем.

5.Бо як гурӯҳи самараноки муҳандисон, ки бо таҷрибаи чандинсола дар соҳаҳои худ дастгирӣ карда мешавад, ширкат кафолат медиҳад, ки ҳар як маҳсулоте, ки воҳиди истеҳсолиро тарк мекунад, дар ҳама ҷиҳат ба дараҷаи баланд аст.

пурсиш
0
Сабади пурсиш
    Сабти дархости шумо холӣ аст
Холӣпурсиш